它通過"/>
品牌: | 荷貝克免維護蓄電池 |
型號: | HC121200 |
參數(shù): | 12V45AH |
單價: | 面議 |
發(fā)貨期限: | 自買家付款之日起 天內發(fā)貨 |
所在地: | 山東 濟南 |
有效期至: | 長期有效 |
發(fā)布時間: | 2023-12-19 07:01 |
最后更新: | 2023-12-19 07:01 |
瀏覽次數(shù): | 75 |
采購咨詢: |
請賣家聯(lián)系我
|
荷貝克免維護蓄電池HCV45AH參數(shù)型號
我們的power.com XC以緊湊的形式代表創(chuàng)新的AGM設計(網格板和羊毛分離器)。它通過后把手進行了優(yōu)化運輸。其特殊的網格板設計確保了大的能量密度。
Wartungsfreiheit hinsichtlichdesNachfüllensvonWasser - durch創(chuàng)新的Gel-ESS Technologie
SehrguteHochstromf?higkeit - geringe Investitionskosten durch innovation Elektrodenstruktur
Optimale Raumausnutzung - durch horizontale Anordnung und Stapelbarkeit
Erh?hteKurzschlusssicherheitschon bei der Montage - durch Verwendung von HOPPECKE System-Verbindern
Einfache Montage und Einbau - Batteriedeckel mit integriertem Griffsystem
Inhalation Sulfuric Acid: Remove to fresh air immediately. Consult a physician. Lead: Remove from exposure, gargle, wash nose and lips; consult physician. Ingestion Sulfuric Acid: Give large of water. Consult a physician. Lead: Consult physician immediately. Skin Sulfuric Acid: Flush with large amounts of water for at least 15 minutes; remove contaminated clothing completely. If symptoms persist, seek medical attention. Wash contaminated clothing before reuse. Discard contaminated shoes. Lead: Wash immediately with soap and water. Eyes Sulfuric Acid and Lead: Flush immediately with large amounts of water for least 15 minutes while lifting lids. Seek immediate medical attention.
閃點(采用的方法):不可燃的可燃極限:*氫氣體滅火劑:ABC級滅火器,限值:Lel=4.1%(氫氣)UEL=74.2% 在牢房里。熱沖擊可能導致電池外殼和/或外殼破裂。在電池充電過程中可能會產生氫氣。特別消防程序:如果有電池 RGE,關閉電源。使用正壓、自給式呼吸器滅火。施加到電解質上的水產生熱量并使其飛濺。耐磨的衣服。VEVE 傾斜區(qū)域良好。 不尋常的火災和爆炸危險: 在正常的電池操作或充電時,電池中會產生氫氣和氧氣氣體。 (氫是易燃的,氧是助燃劑。 (燃燒)在電池過度充電時,這些氣體通過通風口進入空氣。為了避免火災或爆炸的危險,請將火花和其他點火源遠離電池。別這么說 金屬物體同時接觸電池的正負端子。通風良好。
Flash Point (Method Used): non flammable Flammable Limits: *Hydrogen Gas Extinguishing Media: Class ABC extinguisher, Limits: LEL = 4.1% (Hydrogen Gas) UEL = 74.2% NOTE: CO2 may be used, but not directly on the cell. The thermal shock may cause cracking of the battery case and/or cases. Hydrogen gas may be generated during battery charging. Special Fire Fighting Procedures: If batteries are on charge, turn off power. Use positive pressure, self-contained breathing apparatus in fighting fire. Water applied to electrolyte generates heat and causes it to splatter. Wear acid resistant clothing. Ventilate area well. Unusual Fire and Explosion Hazards: Hydrogen and oxygen gases are generated in cells during normal battery operation or when on charge. (Hydrogen is flammable and oxygen supports combustion). These gases enter the air through the vent caps during battery overcharging. To avoid risk of fire or explosion, keep sparks and other sources of ignition away from the battery. Do not allow metal objects to simultaneously contact both positive and negative terminal of batteries. Ventilate area well.
目前UPS電源使用的電池基本上都是免維護鉛酸蓄電池,在使用的過程中,我們都會盡量避免UPS蓄電池深度放電,因為這樣將會影響電池本身的特性,不過也有不同的情況,需要進行深度放電。
UPS蓄電池深度放電管理系統(tǒng),定時自動關機方案。當市電停電后,如果蓄電池組因放電電流較小而使它的放電時間超過原設計的"滿載后備供電時間"時,UPS所允許的長放電時間為原來所預置的蓄電池“后備供電時間”的3倍。當放電時間達到此時刻時,不管ups蓄電池組是否還有足夠的容量可供使用,UPS都將執(zhí)行自動關機操作,不讓蓄電池因放電電流過小而進入"深度放電"工作區(qū)。例如:如果UPS的蓄電池組后備時間為l5min(帶負載),不管用戶的實際負載有多輕,只要市電的停電時間超過45min,UPS都將進入自動關機狀態(tài)(盡管此時的蓄電池還有數(shù)量可觀的可供安全使用的容量存在)。
對UPS電源主機而言,肯定有利于降低逆變器的故障。然而,對于同UPS配套的長延時蓄電池組而言,則會因蓄電池被“深度放電”而造成蓄電池的實際使用壽命成10倍的縮短。所以在使用UPS電源的過程中,應當盡量避免蓄電池深度放電。